200-240VAC 2x16A Dual-Input Switched Rack Power Distribution Unit
1. Power Distribution Unit Product Specification Parameter Description:
Customer name | NO. | Product specification parameter description | ||
Product name | Power switch | 1 | Socket system and number | IEC320 C19 (2); IEC320 C13(8) |
Product specification and model | 1h16QPTKN1D1-8E2G | 2 | Internal connecting line | 16AWG,14AWG,copper Stick |
Product code | 3 | Power supply input mode | C20 socket | |
Product quantity | 4 | Cable plug system | / | |
RoHS | YES | 5 | Cable specifications | / |
Customer product code | / | 6 | Cable installation mode | Back dual input |
Customer product specification and model | 7 | Cable fixing | / | |
8 | Shell color | Black | ||
Special product description | Removable controller | 9 | Size and specification(L*W*H) | 484*250*44mm |
10 | Fixed hole center distance | 465mm | ||
11 | Aluminum alloy shell length | / | ||
12 | Product installation mode | Bracket installation | ||
13 | Installation direction of bracket | Horizontal formal | ||
Factory accessories | 4 pcs for each M6 screw and nut | 14 | Control indication function | 1P/16A CB(Prevent misoperation) |
15 | Protection monitoring function | KN-1 | ||
Product identification | Product name | Power switch | ||
Customer specifications and models | 1h16QPTKN1D1-8E2G | |||
Rated voltage and current | 200-240VAC 2*16A | |||
Safety certification mark | / | |||
LOGO | / | |||
Manufacturer | ESTEL |
2. Power Distribution Unit Product Renderings:
3. Intelligent PDU Function Comparison Table:
Features | Description | Performance Parameters | KN series grade | Notes | |
1 | |||||
Operating supply voltage | The voltage required for the normal operation of the product | AC230V or AC400V | √ | ||
Maximum input and output current | Products can work long-term current | 16A or 32A Or 3x16A or 3x32A | √ | ||
Operating power frequency | The voltage required for the normal operation of the product | 47~63Hz | √ | ||
Access interface | Network port | Access monitoring via Ethernet or LAN | 10/100Mb network adaptation | √ | |
Network port | Level even port | Built-in network switch | Reserving | ||
Serial port | Access through the serial port monitoring | RS485 interface | √ | ||
RS232 interface ( select one with RS485 interface) | √ | Selection | |||
Peripheral interface | Sensor interface | RS485 interface | √ | ||
interview method | HTTP/ HTTPS | Browser mode access | Compatible with IE , FireFox and other popular kernel browsers , supporting SSL | √ | |
TELNET | Simple command line access | / | √ | ||
SSH | Encrypted command line access | Support SSHv2 version | √ | ||
SNMP | Supports common simple network management protocol centralized monitoring | Compatible with protocol versions such as SNMPv1/v2c/v3 | √ | ||
Operating system compatibility | Supports multiple operating systems | The monitoring terminal is compatible with mainstream operating systems such as Windows//win7/linux | √ | ||
Secondary development | For customer system integration | Development agreement TELNET, SSH | √ | ||
RS485 | Support customer agreement customization | √ | |||
Software upgrade | Management software loading | Support management software updates | √ | ||
control | Control each output on and off | Each output breaking capacity 16A 250VAC | |||
Power up and down in sequence | Sequential power-off time interval 0.5s , sequential power-on time interval 1~60s can be set to prevent the power equipment from simultaneously starting the interference equipment, polluting lines, and the total brake line is not on | ||||
Power off | After the PDU input is powered off and restarted, the state of each output switch maintains its original state. | ||||
Monitoring | Detect each output fuse state | Can detect that the fuse is disconnected or the output switch does not turn on and off properly | |||
Monitor input voltage | Resolution : 1V Accuracy: ± 1% +1 word Range: 90~350V | √ | |||
Monitor the total input and output current | Resolution : 0.1A Accuracy: ± 1% +1 word Measuring range: 0.1~40A | √ | |||
Monitor each output current | Resolution : 0.1A Accuracy: ± 1% +1 word Measuring range: 0.1~20A | ||||
Monitor each electrical enery | Resolution : 0.1KW ·H Accuracy: Level 1 | ||||
Monitor each active power | Resolution: 1W Accuracy: ± 1% +1 word | ||||
Monitor each power factor | Resolution: 0.001 Accuracy: ±1%+3 words | ||||
Monitoring total power | Resolution : 0.1KW ·H Accuracy: Level 1 | √ | |||
Monitor breaker status | / | Have not ,but optional | |||
Monitoring ambient temperature | Resolution : 1 °C Accuracy: ± 1% +1 word Measuring Range: -30~100℃ | Have not ,but optional | |||
Monitoring environmental humidity | Resolution : 1% Accuracy: ± 1% +1 word Measuring Range: 01-99% | Have not ,but optional | |||
Monitoring environmental smoke | Maximum effective 25㎡ | Have not ,but optional | |||
Monitoring environmental flooding | Can monitor dew, water immersion environment | Have not ,but optional | |||
Infrared monitoring of environmental personnel entering | Maximum detection distance 16m | Have not ,but optional | |||
Door and window monitoring | Minimum opening distance 5mm effective | Have not ,but optional | |||
Anti-surge, lightning protection failure monitoring | Does not affect the normal use of the product after failure | Have not ,but optional | |||
Alarm limit | Total current limit | Automatic identification of limits | √ | ||
Each output current limit | Automatic identification of limits | ||||
Environmental temperature limits | Automatic identification of limits | √ | |||
Environmental humidity limits | Automatic identification of limits | √ | |||
Alarm output | Each fuse alarm | PS/PN local alarm mode: PDU alarm site inspection, output sound and light, dry contact. PN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH prompt | |||
Each output current limit alarm | |||||
Total current overload warning | √ | ||||
Temperature overrun alarm | Have not ,but optional | ||||
Humidity limit alarm | Have not ,but optional | ||||
Smoke alarm | Have not ,but optional | ||||
Flooding alarm | Have not ,but optional | ||||
People enter the alarm | PN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH prompt | Have not ,but optional | |||
Open door / window alarm | Have not ,but optional | ||||
Anti-surge, lightning failure alarm | Have not ,but optional | ||||
Display, instructions | Output indicator | One output per indicator | Have not ,but optional | ||
LCD display | Display current voltage, display product information, alarm information | √ | |||
Digital tube display | Display current voltage, display product information, alarm information | ||||
Key menu operation | search information | Query display product information, alarm information, current, etc. | √ | ||
On / Off alarm sound and dry contact | Turn off / on alarm sound and dry contact output. Dry contact output has two options, normally open and normally closed. Passive, contact can be connected to 2A 250VAC. | √ | |||
Protection | Lightning surge | Differential mode: ± 2kV Common mode: ± 2KV Through traffic : 3KA Discharge current: 5KA | Have not ,but optional | ||
Each with a fuse | Insurance tube breaking force 1500A; To prevent the main line from being powered off, disasters occur in the power equipment and lines, and the fuse can be equipped with 0.1~16A | Have not ,but optional | |||
Circuit breaker protection | Switch the power supply to prevent short circuit affect the main line, to prevent electrical equipment overload disaster, breaking force 5000A | Have not ,but optional | |||
Recoverable overload protection | Preventing Overload from Electrical Equipment and Disasters | Have not ,but optional | |||
Record | Alarm log | Cyclic alarm log, you can query, export, save, delete | √ | ||
Management | User management authority | Distinguish between administrator and general personnel rights | √ | ||
Output group management | / | √ | |||
Clock synchronization | Correct product system clock | √ | |||
Named management | Supports naming operations such as PDUs , output bits, and sensors for easy management | √ | |||
Intelligent Recognition | Intelligent identification output | Automatically identify the output format, number of digits | √ | ||
Intelligent identification sensor | The sensor interface does not need to be defined. The access can identify the sensor type and quantity. | √ | |||
Intelligent identification limits | When the limit is out of range, the setting is invalid | √ | |||
Intelligent identification of the product's maximum output current and current product access device power | Helps managers control the number or type of product access | √ | |||
Intelligent identification of power factor | Help customers understand the power consumption of customer equipment and can be used as a reference for energy consumption | √ | |||
Sensor access | 1~8 same or different types of sensors connected at the same time | Sensor access, expansion, and flexibility to design new sensors based on new customer needs | √ | Have not ,but optional |