Tianjin Estel Electronic Science and Technology Co.,Ltd
TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD (ESTEL(GUANGDONG) TECHNOLOGY CO., LTD) We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom
Add to Cart
Outdoor Telecom Equipment Cabinets ET6565150-A24U With Aircon And Front Back Door
1. Outdoor Telecom Equipment Cabinets
An telecom equipment cabinets, also known as an outdoor equipment enclosure, is typically designed to protect sensitive telecommunications equipment from harsh environmental conditions. These cabinets are commonly used to house equipment such as routers, switches, power supplies, and other network devices.
Outdoor communications cabinets are typically made of durable materials such as steel or aluminum to provide protection from weather elements like rain, snow, and extreme temperatures. They are often equipped with features like weatherproof seals, cooling systems, and security locks to ensure the safety and functionality of the enclosed equipment.
2. Telecom Equipment Cabinets Advantages
Telecom equipment cabinets, also known as network equipment cabinets or server cabinets, are specialized enclosures used to house and protect various types of telecommunication and networking equipment. These cabinets are essential components in telecom infrastructure to ensure the safe operation of sensitive electronic equipment.
Here are some features and aspects of telecom equipment cabinets:
Security: Telecom cabinets often come equipped with locks or security mechanisms to restrict unauthorized access to the equipment housed within, ensuring data security.
Ventilation and Cooling: Proper ventilation and cooling systems are integrated into the cabinets to regulate temperature and prevent overheating of the electronic components.
Rack Space: Telecom cabinets are designed to accommodate standard rack-mounted equipment such as servers, routers, switches, modems, and other networking devices.
Cable Management: They include provisions for efficient cable management to organize and route cables neatly, ensuring easy access for maintenance and troubleshooting.
Modularity and Flexibility: Many cabinets are modular and customizable to accommodate various equipment configurations and allow for future expansions or upgrades.
Durability: Telecom equipment cabinets are built with robust materials to withstand environmental factors, physical impacts, and provide long-term durability.
EMI/RFI Protection: Some cabinets offer electromagnetic interference (EMI) and radio frequency interference (RFI) shielding to prevent signal interference and ensure equipment reliability.
Outdoor vs. Indoor: Telecom cabinets come in indoor and outdoor variants, with outdoor cabinets featuring additional weatherproofing and protection against elements.
Telecom Applications: These cabinets are widely used in telecommunications facilities, data centers, server rooms, network installations, IoT deployments, and many other industries requiring networking infrastructure.
By providing a secure, organized, and controlled environment for telecom equipment, these cabinets play a critical role in maintaining the efficiency, reliability, and security of modern communication networks.
3. Technical Parameters of Equipment Cabinets
Item | Type | Technical Parameter |
Structure | Dimension | External Dimension: W×D×H 650x650x1500mm |
Layout | 1 compartment | |
Equipment Installation Method | 19” rack, 24U | |
Door | With one front door and one back door, and three point lock for outdoor cabinet (support padlock) | |
Material | Galvanized steel, single wall with insulation | |
Heat Insulation | 20mm PEF | |
Ingress Protection | IP55 | |
Temperature Control | Cooling | Air conditioner AC220v,50Hz Cooling Capacity:600W |
Lighting | LED lamp | LED lamp |
Temperature | Temperature | Working Temperature: -40°C ~ +55°C |
Storage Temperature: -50°C ~ + 70°C | ||
Transport Temperature: -50°C ~ +70°C | ||
Humidity | Relative Humidity | 5% ~ 100% |
Pressure | Air Pressure | 62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity | Solar Radiation Intensity | 1120 × (1±5%) W/m2 |
5. Equipment Cabinets Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Equipment Cabinets | 1 | Set | (1) External Dimension W×D×H 650x650x1500mm (2) One compartment: including 24U standard 19" rack (3) With one front door and three point anti-theft lock for outdoor cabinet(support padlock) (4) Material: galvanized steel; single wall with heat insulation (5) IP level: IP55 (6) Cable entry on the bottom (7) Including grounding copper bar |
2 | Air Conditioner | 1 | Set | Air conditioner Cooling capacity: 600W, Power Supply: AC220V, 50Hz |
3 | Fan | 1 | Set | Two AC220V fan and one temperature controller |
4 | Environment Monitoring System | 1 | Set | 1× environment monitoring unit,19”, 1U; AC220V, support RS485 and SNMP communication 1× smoke sensor, 1× water sensor, 1× temperature sensor, 1× door sensor. |
5 | AC and DC Power Distribution Unit | 1 | Set | Grade B Lightning Proof AC Input: 63A/2P×1; AC Output: 16A/1P×4; DC Output: 16A/1P×4; Height: 4U |
6 | LED Lamp Switch | 1 | PC | Used for controlling LED lamp on/off |
7 | LED Lamp | 1 | PC | AC220V, used for illumination in the cabinet |
8 | Package | 1 | Set | Wooden Case |
6. How to design a Equipment Cabinets :
Designing a telecom cabinet involves several steps to ensure that it meets the specific technical requirements and operational needs. Here is a general guide on how you can design a telecom cabinet:
Define Requirements: Start by clearly defining the requirements for the telecom cabinet. Consider factors such as size, capacity, cooling requirements, power distribution, cable management, security features, and environmental considerations.
Select Cabinet Type: Choose the type of cabinet that best suits your needs, whether it's a wall-mounted cabinet, floor-standing cabinet, outdoor cabinet, or a custom-designed solution.
Layout Planning: Create a layout plan for the cabinet that includes the placement of equipment such as servers, switches, routers, power supplies, batteries, and other components. Pay attention to airflow, cable routing, and accessibility for maintenance.
Choose Materials: Select suitable materials for the cabinet construction based on factors like durability, thermal properties, and electromagnetic compatibility (EMC). Common materials include steel, aluminum, or other materials with protective coatings.
Ventilation and Cooling: Ensure proper ventilation and cooling systems are in place to maintain optimal operating temperatures for the equipment inside the cabinet. Consider adding fans, vents, or air conditioning units as needed.
Power Distribution: Design an efficient power distribution system within the cabinet, including power outlets, surge protection, circuit breakers, and backup power solutions like batteries or UPS (uninterruptible power supply) systems.
Cable Management: Implement cable management solutions to organize and secure network cables, power cords, and other connections within the cabinet. Use cable trays, tie wraps, labels, and color-coding for easy identification.
Security Features: Incorporate security features such as locks, access control systems, tamper-proof mechanisms, and surveillance cameras to protect the equipment inside the cabinet from unauthorized access or physical damage.
EMC Considerations: Ensure that the cabinet design takes into account electromagnetic compatibility (EMC) requirements to minimize interference and ensure proper functioning of sensitive electronic equipment.
Testing and Validation: Before deployment, conduct thorough testing and validation of the telecom cabinet design to ensure it meets all specifications, functions correctly, and complies with relevant industry standards.