35U Rack Power Distribution Outdoor Power Cabinet One Front Door With Air Conditioner And Fan
1. Outdoor Power Cabinet Specifications
ET231726812919035 is an outdoor cabinet which can protect customer’s equipments from damage and extreme weather conditions.
The cabinet is an ideal solution for physical connections of outdoor telecommunication equipments. Both active telecom equipments and passive telecom equipments can be accommodated inside the cabinet.
(1) The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
(2) The cabinet cooling use one air conditioners, which work in alternation to continuously keep thermostatic inside the cabinet.
(3) The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.
(4) All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.
(5) The cabinet uses assembled structure, easy for installation.
(6) The cabinet includes 19” standard installation rack.
Material: good quality galvanized steel
Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
Cabinet load bearing: ≥600kg
Ingress protection: IP55
Flame retardance: comply with GB5169.7 test A
Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
Mechanical strength: each surface can bear upright pressure >980N; after the door is
3. Technical Parameters
Item | Technical Parameter | |
Cabinet | Model | ET231726812919035 |
Protection Level | IP65 | |
External Dimension | H1970mm×W680mm×D1290mm | |
Internal Dimension | 19 inch rail, 35U | |
Material | Galvanized steel, 1.2mm thickness, single wall. Thickness of bearing parts: 2.0mm | |
Insulation | PEF | |
Coating | Polyester powder coating | |
Color | RAL7035 | |
Lock | Anti-theft four-point locking system | |
Hinge | Inner hinge | |
Installation Options | Floor mounted, roof mounted ,wall mounted . | |
Cable Routing | Cable in and out from the bottom of cabinet | |
Maintenance | One front door and one rear door | |
Cooling | Air conditioner | 2000W 48VDC |
auxiliary fan | DC 48V , Adjustable temperature (with fan temperature control) | |
Power distribution unit | 1. Ac switchboard with transient voltage suppressor diode (SPD 80KA) Power grid and diesel generators (L1, L2, N, G) 120V Nema 5-15R 2-position socket 1, double circuit breaker 100A 2, single circuit breakers 64A 3, single circuit breakers 30A 2. Power distribution unit Input voltage: AC 220V (L1, L2, N and G) 60Hz Single phase (L1, L2, N and Earth) 3. Connect the generator Input voltage: AC 220V (L1, L2, N and G) 60Hz
| |
Others | Illumination | LED lamp: 220VAC 50Hz |
Environment | Working Temperature | -40℃ ~+55℃ (+Solar Radiation) |
Storage Temperature | -40℃~+70℃ | |
Working Humidity | 5%~95%(No condensation) | |
Working Altitude | 0~4000 meters |
4.Telecom cabinet installation typically involves the following steps:
(1) Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
(2) Door hinges use inner hinge mode.
7. Quality Control Introduction
Quality control is an essential aspect of telecom cabinet manufacturing to ensure that the final product meets the required standards and specifications. The following are some common quality control measures that are typically taken during the production of telecom cabinets:
1.Raw material inspection: The quality control process begins with the inspection of raw materials used in the production of the cabinet. This includes inspecting the metal sheets, screws, hinges, and other components to ensure that they meet the required quality standards.
2.Production process inspection: During the production process, the cabinets are inspected at various stages to ensure that they meet the required specifications. This includes checking the dimensions, angles, and tolerances of the cabinet components.
3.Surface finish inspection: The surface finish of the cabinet is also inspected to ensure that it is free from any scratches, dents, or other defects that may affect the overall appearance and functionality of the product.
4.Functionality testing: Once the cabinet is fully assembled, it undergoes functional testing to ensure that it can perform its intended functions. This includes testing the cooling system, power supply, and other components to ensure that they are working correctly.
5.Packaging and shipment inspection: The final step in the quality control process involves inspecting the packaging of the cabinet to ensure that it is adequately protected during shipment. This includes checking for any damages or defects that may have occurred during the shipment process.
Our company resolutely implements the principle of quality first, we control and supervise the whole production process in strict accordance with the requirements of the ISO9001 system and the related implementation process. The quality department strictly controls all aspects like material inspection, production processes, product testing, shipment inspection and establishes traceable documents and product identification.
Our quality inspection team, is very familiar with the various standards, strict implementation of the standards required sampling and testing methods.