The outdoor cabinet is widely used in telecom operators’ mobile telecommunication sites, outdoor small shelters, railway electrical control cabinets, electronic police, communication base stations, outdoor air detection stations, solar control cabinets,etc.
Compact and light double-walled design
Highest protection against corrosion
Features an integrated roof
Thickness of plate: 1.5mm
with heat insulation ,Polyester powder coat with UV protection
PUR non-porous gasket—suitable for extreme temperatures
Fully welded design, supplied complete, no assembly required
Surface finish: Degreasing, pickling, phosphoric wash, cleaning, and powder coated
This cabinet is 1800mm High and 1000mm Wide and 1000mm Deep. This cabinet represent a suitable solution for projects with high requirements on stable in-rack climate. They are specifically designed for mounting onto a column.
● Cooling solution: We adopt Air conditioner to control temperature ensuring the best working condition inside the cabinet.
● Power distribution unit: can meet the requirements of power system normal operation and equipments maintenance
●Sensors: can monitor internal temperature,humidity,fire/smoke,door opened state.
● Light: one piece LED tube light is for lighting insde and fixed on the top cover.
● Strong rack inside to be equipped with telecom equipments, power source, temperature control device and other attachments.
● Digital display the temperature-setting, temperature alarm, temperature parameters inside and outside, and all kinds of other alarm information, etc.
Configuration | Item | Technical Parameter |
Cabinet | Model | ET1111210010018033 |
Protection Level | IP56 | |
External Dimension | H1800mm×W1000mm×D1000mm | |
Internal Dimension | 19 inch rail | |
Material | thickness of plate: 1.5mm | |
Insulation | 20mm PEF | |
Coating | Polyester powder coating | |
Color | RAL7035 | |
Door | One front door and one rear door, anti-theft three-point locking system. | |
Hinge | Inner hinge | |
Installation Options | Floor mounted | |
Cable Routing | Cable in and out from the bottom of cabinet | |
Cooling | DC air conditioner | Cooling Capacity: 500W, Input Voltage: 48VDC |
Power Distribution Unit | AC Input:1×2P/63A AC SPD:SPD40/60KA AC Output:5×1P/16A DC Output:1×1P/32A,2×1P/16A,2×1P/6A | |
Sensors | 2pcs × Door sensor, 1pc ×temperature and humidity sensor | |
Others | 48VDC LED lamp for illumination. 2pcs | |
Environment | Working Temperature | -40℃ ~+55℃ (+Solar Radiation) |
Storage Temperature | -40℃~+70℃ | |
Working Humidity | 5%~95%(No condensation) | |
Working Altitude | 0~4000 meters |
The cabinet includes 19” equipment installation rack. The cabinet includes two air conditioners, one installed on front door and another installed on back door.
The cabinet includes one front door and one back door. The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.
(1) Applicable environment conditions:
Operating temperature: -40°C ~ + 55°C
Storage temperature: -50°C ~ + 70°C
Transport temperature: -50°C ~ + 70°C
Relative humidity (RH): 5%~99%
Air pressure: 62kPa ~ 101kPa (similar to 0m ~ 5000m altitude)
Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.
LED lamp, LED lamp sensor, smoke sensor, door sensor and temperature & humidity sensor are installed at the top of the cabinet.
Water sensor is installed at the bottom of the cabinet.
PDU and environment monitoring unit are installed on 19” rack.
The cabinet includes totally two air conditioners, one air conditioner installed on front door and the other installed on back door.
Cable Inlet
Feeder cable and other external cables all use bottom wiring method.
Grounding Protection