Tianjin Estel Electronic Science and Technology Co.,Ltd

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD (ESTEL(GUANGDONG) TECHNOLOGY CO., LTD) We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Environment Monitoring System /

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Contact Now
Tianjin Estel Electronic Science and Technology Co.,Ltd
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsFiona Liang
Contact Now

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Ask Latest Price
Video Channel
Brand Name :ESTEL
Model Number :NEM-500
Certification :ISO9001, CE, 3C, FCC, TLC
Place of Origin :Shenzhen, China (Mainland)
MOQ :1
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, Western Union
Supply Ability :20,000 sets per month
Delivery Time :7-10 working days
Packaging Details :carton/wooden case
Application :Outdoor Telecom Cabinet
Analog Input :four ways
Digital Input :eight ways
Communication Interface :RS485, Ethernet, RS485/232 multiplex
MTBF :>50000 hours
Operating Voltage :85 VAC to 300 VAC , or 20 VDC to 60 VDC
Monitored Sensors :door sensor, smoke sensor, water sensor, temperature and humidity sensor, etc.
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Communication Interface: RS485, Ethernet, RS485/232 multiplex
Brand Name: ESTEL Analog Input: four ways
Model Number: NEM-500 Digital Input: eight ways
Product Name: Environment Monitoring System Dry contact (relay) output:eight ways
Certification: ISO9001, CE, 3C, FCC, TLC Operating Voltage: 85 VAC~300 VAC, or 20 VDC~ 60 VDC
Application: Outdoor Telecom Cabinet Alarm Sensors: door sensor, smoke sensor, water sensor, temperature and humidity sensor, tilt & shock combination sensor

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

1. Description

The NEM-500 is a small high-reliability environment monitoring unit developed to provide environment/device control and remote monitoring for communications base stations, integrated equipment rooms, and out-door cabinets.

The monitoring unit monitors important environmental factors such as temperature, humidity, smog, water penetration, access control, vibration/leaning, main distribution frame (MDF), and surge protection device (SPD). When any value collected by a sensor exceeds the preset threshold, an alarm is sent through the LCD, buzzer, or system log.

The monitoring unit also provides complete device detection functions, such as switch power status detection. Through a preserved custom interface (optional), the unit can be connected to another sensor in main contact point output type.

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

2. Product Appearance

Chassis dimensions (H x W x D) are 43.6 mm (1U) x 482.6 mm (19 inches) x 122 mm. Front cabling is adopted. The following shows the front panel of the chassis:

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Note: The diagram is for reference only and the dimensions may be different from those of the real device. Note: In this document, transmitter, sensor, and integrated transmitter have the same meaning.

Interface specifications

1.)Power switch

It is used to power on/off the device.

2.)Power interface

This device can be powered by AC or DC power supply.

AC voltage range: 85 VAC to 300 VAC;

DC voltage range: 20 VDC to 60 VDC

3.)Liquid crystal display (LCD)

It displays sensor status data and parameter configuration pages.

4.)Buttons

They are used together with the LCD for menu page up/down and parameter settings.

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232UP: Go to the previous page up (when viewing), or increase the parameter value (when setting);

DOWN: Go to the next page up (when viewing), or decrease the parameter value (when setting);

OK: Confirm the selection of a menu option (when viewing), or of a parameter value (when setting).

5.)LEDs

They show the operation and alarm status of the monitoring unit.

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Power LED: It indicates that the device is powered on and running;

Minor alarm: It indicates a minor alarm;

Major alarm: It indicates a major alarm.

6.)Sensor input interfaces

Four current-type analog input ports, with 12 VDC power ports connected to temperature, or temperature and humidity combination sensors;

Eight switch (dry contact) input ports, three of which with 12 VDC power ports connected to access control, smog detector, infrared detector, or SPD sensors;

8.)Dry contact (relay) output interfaces

Eight ports are available to send alarm signals to the upper-level alarm center, or to control the device’s startup/close-down.

You can customize alarm rules, and associate any alarm signal with a relay among O1 to O8. Ports O1 to O4 output switch signals;

Ports O5 to O8 control large-current devices such as fans and heaters.

9.)RS485/RS232/Ethernet interfaces

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232Four ports: A is an optional Ethernet port; B and C are fixed RS485 ports; D is an RS485/RS232 multiplex port that can be set to work in either RS485 or RS232 mode. Port A, D can be switch by the system automatically.

Ports A and D are used to connect the remote computer or alarm center device;

Ports B and C are used to connect other RS485-interface devices, such as the switch power, air conditioners, heat exchangers, and temperature and humidity sensors. (Note: Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols.)

Configuration and cabling diagram:

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Specifications of the Environment Monitoring System

Model

NEM-510

NEM-520

NEM-530

Analog input port (4 mA to 20 mA)

4

4

4

Dry contact (Digital) input port

8

8

8

AC voltage detection (single phase)

/

1

1

DC voltage detection

1

1

1

Dry contact (relay) output port

8

8

8

RS485 interface (fixed)

2

2

2

RS485/RS232 multiplex interface for uploading (Can switch between RS485/RS232)

1, fixed to RS485

1, RS485/RS232

multiplex

1, RS485/RS232

multiplex

Ethernet

1, optional

1, optional

1, optional

Water detection sensor module

Supported,

optional

Supported,

optional

Supported,

optional

Thermostat (Control fans)

/

Supported,

optional

Supported,

optional

Thermostat (Control heater)

/

Supported,

optional

Supported,

optional

AC power (220 V) supply

Supported,

optional

Supported,

optional

Supported,

optional

DC power (48 V) supply

Supported,

optional

Supported,

optional

Supported,

optional

Remote computer monitoring software

Controllable heat exchanger

/

/

Supported,

optional

Monitored air conditioner

/

/

Supported,

optional

Monitored switching power

/

/

Supported,

optional

Monitored Smart Air-Conditioning

Remote Control

/

/

Supported,

optional

3. Features

3.1 Front maintenance (front cabling): higher space utilization and easy maintenance

3.2 Combat structure: standard 1U/19-inch chassis for easy installation

3.3 Monitoring of cabinet switch power: The monitoring unit can be connected to the switch power for transparent data transmission and forwarding. The complete monitoring functionality is to be developed based on standard communications protocols.

3.4 Uploading over standard protocols: The monitoring unit uploads environment data to the monitoring background and receives remote system commands over specified protocols in main contact point or RS485/232/IP mode.

3.5 Complete monitoring functionality: The monitoring unit intelligently controls all environment devices in an equipment room, and automatically monitors environment parameters against the alarm thresholds from remote.

3.6 GUI-based host computer control software:

3.7 Various sensors supported: The monitoring unit can be connected to various analog-output sensors, switch-output sensors, and RS232, RS485 interface sensors.

3.8 Built-in common sensors for simplified cabling during monitoring system installation Optional built-in DC power failure sensor, AC power failure sensor, and water sensor

3.9 Flexible power supply mode: voltage range as 85 VAC to 300 VAC, or 20 VDC to 60 VDC

4. Product Specifications

Environment variables

No. Variable Specification Description
1

Temperature

/Humidity

4

Four port supports 4 mA to 20 mA current-type sensor;

The port supports 4 temperature sensor, or 2 temperature/humidity combination sensor.

2 Water detection 2

Leaking and water penetration detection

One port has a built-in sensor and you only need to connect the outside of the chassis to the pole;

The other external port is connected to the external water sensor

(Dry contact interface).

3 Access control 1 Door status (open/close) detection
4 Smoke 1 Smoke and fire detection
5 AC power failure alarm 1

Single-phase AC voltage detection

One sensor is built in and the AC power cable must be connected to the local detection terminal.

6 DC power failure alarm 1

DC voltage detection

One sensor is built in and the DC power cable must be connected to the local detection terminal.

7 SPD 1 SPD status detection (Dry contact interface)
8 MDF 1 MDF status detection
9 Switching power 1

Switching power status detection (RS485 connection in standard configuration)

Optional RS232 serial port connection (through RS485-RS232

No. Variable Specification Description

Converter)

Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based on standard communications protocols.

10 Custom 2

One port is connected to the switching power failure sensor (Dry contact interface) by default;

The other port is connected to a custom dry contact type sensor,

with 12 V power supply for external sensors.

Output ports

No. Variable Specification Description
1 Dry contact output 8

Custom output signal type:

O1/O2/O3/O4 are small-current output ports;

O5/O6/O7/O8 are large-current output ports, with relay contact capacity as 5 A 250 VAC and 5 A 30 VDC.

Communication ports

Four ports are configured as follows:

No. Interface Type Specification Description
1 RS485 2

It is connected to the RS485 port of an intelligent device. Transparent data transmission and forwarding are supported. The complete monitoring functionality is to be developed based

on standard communications protocols.

2 Ethernet 1 (optional)

It is connected to a remote computer or alarm center over

TCP/IP.

3

RS485/232

multiplex

1

It is connected to a remote computer or alarm center.

The interface type is RS232 or RS485 (RS485 by default).

Note: Items 2 and 3 cannot coexist.

5. Functions

  • Signal collection function

The monitoring unit collects data of environment variables (such as temperature, humidity, smog) and device variables (such as switch power), passes the data for multipoint control unit (MCU) processing and analysis, and shows the equipment room status on the local liquid crystal display (LCD) or remote computer;

  • Alarm function

An alarm is sent when any value collected by a sensor exceeds the preset threshold;

  • History record function

Historical alarms can be queried.

  • Local or remote control function

Local users can press the front panel buttons to query and set parameters and data;

The monitoring unit communicates with the host computer through the Ethernet (IP)/RS232/RS485/main contact point interface, and the host computer can read all status data of the monitoring unit and modify system settings from remote.

The remote control software for the host computer is optional.

6. Packing and Shipping

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Remote Monitoring Environment / Security Monitoring System Support RS485 RS232

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

7. Our Contact Information

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Inquiry Cart 0