Brand Name :ESTEL
Model Number :GPE48300A
Certification :ISO9001, CE, 3C, FCC, TLC
Place of Origin :Shenzhen, China (Mainland)
MOQ :1
Price :negotiation
Payment Terms :L/C, D/A, D/P, , T/T, Western Union
Supply Ability :20,000 sets per month
Delivery Time :7-10 working days
Packaging Details :carton/wooden case
Output Power :16050W
Input Frequency :45~65Hz
Application :outdoor telecom cabinet
Feature :output over current protection
Input Voltage :AC220V
Installation Mode :19” rack
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Transmission Equipment Telecom Rack Mount Rectifier With Output Over Current Protection

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Input Voltage: AC220V
Brand Name: ESTEL Output Voltage: DC48V
Model Number: GPE48300A Output Power: 16050W
Product Name: Telecom Power System Input Frequency 45~65Hz
Certification: ISO9001, CE, 3C, FCC, TLC Max. Input Current: 81A
Installation Mode: 19” installed Output efficiency: 92%
Application: outdoor telecom cabinet Operating temperature range: -25°C~+55°C

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 20,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

1. Application

(1) Small scale program controlled exchangers

(2) Access network

(3) Transmission equipment

(4) Mobile communication

(5) Satellite communication ground station

(6) Microwave communication

2. Feature

(1) Adoption of active power factor compensation technology with factor >0.99

(2) Wide operating range of AC input voltage: 90~280Vac

(3) Operating temperature range: -25°C~+55°C

(4) Zero current/voltage switching tech with high efficiency ≥92%

(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, low voltage protection etc.

(6) Hot-swappable

(7) Input over/under voltage protection

(8) Output over voltage protection

(9) Output over current protection

(10) Output short circuit protection

(11) Auto current sharing, parallel output

(12) Integrated mounting

(13) Perfect SPD 80KA (8/20 US)

3. Description

The GPE48300A integrated power system consists of power distribution, integrated cabinet, monitoring module and rectifier module. The whole system is of high reliability and performance, and can be operated through PC software.

4. GPE48300A System Configuration

GPE48300A consists of integrated cabinet, power distribution, rectifier module (from 1 set, up to 7 sets) and 1 monitoring module. The configuration is optional, as following table:

Configuration Rectifier Module Monitoring Module Power Distribution
Standard GPR4850D GPM48P

AC power distribution: single phase input, 1-pole AC breaker @ general line (63A/3P);

DC power distribution: battery MCB 200A×2;

LVLD: 63A×4;32A×4(MCB capacity optional)

LVBD: 32A×2; 16A×2 (MCB capacity optional)

5. GPE48300A Operating Principle

AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. LVLD and LVBD are connected with 2 load power down contactors KM1, KM2. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.

Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retaining power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.

6. GPE48300A Properties

Input
Parameter Min. Typical Max. Unit Remark
Input voltage range 90 220 280 Vac
Input frequency 45 50 65 Hz
Input current 81 A

Output
Parameter Min. Typical Max. Unit Remark
Output voltage range -42 -53.5 -58 Vdc
Output current range 0 300 A 176~280VAC
0 150 A 90~176VAC
Ripple (Vp-p) 200 mv At rated input/output, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz.
Output efficiency 90 92 % 220Vac input
83 85 % 110Vac input
Regulation ±1 %
Load regulation ±1 %
Line regulation ±1 %

Insulation rating
Parameter Min. Typical Max. Unit Remark
Input-chassis 2121 Vdc
Input - output 2121 Vdc
Output - chassis 750 Vdc
Insulation resistance At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

Ambient requirements
Parameters Min. Typical Max. Unit Remark
Operating temp -25 55 °C When ≥55°C, power derating output; +55~+65°C, with temperature going up, linear derating 2.0%/°C.
Extension operating temp -40 65 °C -40°C, power can start, index allowing degradation.
Storage tempStorage temperature -40 80 °C
Humidity 10 90 % Relative humidity, no condensing
Atmospheric pressure 70 106 KPa
Altitude 0 3000 m
Cooling method Forced cooling with fan
Ingress protection The unit can operate normally when the diameter of dust particle is more than 5µm, with density ≤3*104 /m3. The dust shall not be conducting, electromagnetic or corrosive.

Notes:

(1) 55~65°C, module power derates, derating method is auto derating; 65°C, 176~280Vac, long term regulate output at least 80% rated power.

(2) 55°C, can output max. output power of module, without over temperature protection, and components can operate normally.

(3) Bacause of liquid crystal’s feature, when exceeding liquid crystal operating temperature range, the screen may be over bright or turn dark with no display.

(4) When lots of dust enter module, short circuit may happen to circuit inside the module. Under damp weather, after dust absorb water, insulation inside power decreases, which may lead to creepage or short circuit inside module. Therefore, in places with lots of dust, please take dust proof measure and clear dust-proof mesh and dust inside module. If dust is too much, the fan may be blocked. The module is cooled by fans, not enough air volume may cause hot inside module can’t be dissipated, then the module will enter over temperature protection in advance.

7. Electrical Connection Instruction

Chassis connects with external electric through system interface board. As shown in figure below:

Transmission Equipment Telecom Rack Mount Rectifier With Output Over Current Protection

Connector Instruction:

1. System, Battery Anode Copper Bar

2. LVLD

3. AC Input: N: Neutral Wire; L1, L2, L3: Live Wire

4. DC SPD

5. B1-, B2-: battery cathode

6. LVBD

7. AC SPD

8. Packing and Shipping

Transmission Equipment Telecom Rack Mount Rectifier With Output Over Current Protection

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

9. Our Contact Information

Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Inquiry Cart 0