Tianjin Estel Electronic Science and Technology Co.,Ltd

TIANJIN ESTEL ELECTRONIC SCIENCE AND TECHNOLOGY CO.,LTD (ESTEL(GUANGDONG) TECHNOLOGY CO., LTD) We are the professoinal supplier of outdoor telecom cabinet, air conditioner, heat exchanger, and telecom

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Outdoor Cabinet Air Conditioner /

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Contact Now
Tianjin Estel Electronic Science and Technology Co.,Ltd
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsFiona Liang
Contact Now

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Ask Latest Price
Video Channel
Brand Name :ESTEL
Model Number :TC06-200JFH/01(KT029)
Certification :ISO9001, CE, 3C, FCC, TLC
Place of Origin :Shenzhen, China (Mainland)
MOQ :1
Price :negotiation
Payment Terms :L/C, D/A, D/P, T/T, etc
Supply Ability :10,800 sets per month
Delivery Time :7-10 working days
Packaging Details :carton + wooden case
Rated Input Power :616W
Working Temperature :-20°C ~ +55°C
Application :UPS room
Installation :door mounted
Rated Input Current :2.8A
Cooling Method :compressor, active cooling
Dimension :H×W×D 750×500×230mm
Refrigerant :R410a
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Quick Details:

Place of Origin: Shenzhen, China (Mainland) Rated Cooling Capacity : 2000W
Brand Name: ESTEL Rated Heating Capacity:300/500W (optional)
Model: TC06-200JFH/01(KT029) Dimension: H×W×D 750×500×230mm
Product Name: Outdoor Cabinet Air Conditioner Input Voltage: AC220V/50Hz
Certification: ISO9001, CE, 3C, FCC, TLC Rated Input Current: 2.8A
Cover: including outer cover Rated Input Power: 616W
Color: grey Working Temperature: -20°C ~ +55°C
Protection Level: IP55 Noise: ≤65dB
Installation Mode: door mounted, side mounted Refrigerant: R410A
Support OEM Cooling Method: compressor, active cooling

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: T/T, L/C,DA,DP, etc
Supply Ability: 10,800 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton + wooden case

1. Specifications

(1) Technical Parameters

Environmental Performance working environmental temperature -20°C ~ 55°C
storage temperature -40°C ~ 70°C
working humidity ≤95%
Thermal Performance rated cooling capacity

2200W(L35 L35)

2000W(L25 L35)

rated heating capacity 300/500W (optional)

Electrical Performance

rated input current

3.0A(L35 L35)

2.8A(L25 L35)

rated input power

660W(L35 L35)

616W(L25 L35)

rated input voltage AC220V~240V/50Hz
Refrigerant R410A
Noise ≤65dB

Dimension Diagram: H×W×D: 750×500×230mm

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Model A B C D E F G H I J K

TC06-200JFH/01

(KT029)

220 474 460 600 724 750 198 230 700 450 500

Door Hole-opening Diagram(mm):

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Size

Model

Specs L M N O P Q R

TC06-200JFH/01

(KT029)

2000W 474 460 220 724 708 600 460

Installation Diagram:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

2. Description

Cabinet air conditioner is actively cooling with compressor, and it will remove the heat inside the cabinet to outside. It can also keep the dust and heat outside the cabinet, avoiding problems from using fans. The cabinet inside can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system.

3. Application

The air conditioner is widely used for outdoor telecommunication cabinet, battery cabinet, electric cabinet, industry control cabinet, power cabinet, rectifier cabinet, UPS cabinet, BTS cabinet etc.

4. Features

  • Strong adaptability
  • High intelligence
  • High precision
  • High reliability
  • Low noise
  • Low energy consumption
  • With 4 way switching value detection
  • With 1 way room air conditioner control
  • Voltage input range: 220VAC±15% 50Hz
  • With dry contact alarm output

5. System Principle Diagram

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

6. Electrical Wiring Diagram

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Wiring Ports:

L N PE : power supply port (voltage input: 220VAC±15% 50Hz)

F+ F- : direct ventilation output port

AL1 AL2: general alarm output port

A+ B- SGND: RS485 communication port

N: not connected pin

7. System Control

7.1 Function and Application

ET731 intelligent air conditioner controller is a universal intelligent controller, controlling with highly integrated STC SCM. It can intelligently control thermostatic cabinet air conditioner working and hydrogen exhausting, including functions such as fault self diagnosis, power-on self start, or restart after unexpected failure caused by other reasons. The controller is compatible with all types of air conditioners in the market.

The controller, with the features of advanced performance, easy installation and setting, are widely used in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.

7.2 Technical Parameter

  • 2×16 Chinese/English shift LCD display, user friendly;
  • Simultaneously display temperature and humidity inside the box and communication room temperature;
  • Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:5%;
  • Can store 180 days’ daily event record, 1 record every day;
  • Daily highest temperature, lowest temperature, average temperature
  • Daily event record;
  • Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
  • RS485 communication, YD/T 1363.1-2005 standard protocol, support remote detection and control;
  • Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner)
  • Real-time control air conditioner on/off
  • Power supply: AC185V~264V/50Hz;
  • Power consumption:≤5W;
  • Working environment: -30°C~70°C; <90%RH;
  • Installation method: guide rail, hanging;
  • Dimension(L×W×H):150mm×190mm×45mm

7.3 Operating Instruction

ET731 uses English interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

a. Check operating parameters of key parts inside air conditioner, namely observation parameter. Operation steps:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Observation Parameter: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

b. Revise operating parameters of air conditioner, namely control parameters. Operation steps:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Control Parameter: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

c. Revise basic parameters of air conditioner. Operation steps:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Basic Parameter: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.

d. Manual Operation Mode:

Operation steps:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Enter the interface to select “Cool” (cooing), “Heater” (heating), “Air” (direct ventilation) to conduct manual start (ON) and stop (OFF) operation.

e. Event Query Mode:

Operation steps:

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

8. Mainboard Wiring Diagram

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

9. Packing and Shipping

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Outdoor Cabinet Air Conditioner / Panel Board Air Conditioner For Outside Plant Access Cabinet

Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.